Dutch website version

3000

Previous Next

Level Transmitter 8000 with metallic diaphragm

The all stainless series 8000 level transmitter has a flush diaphragm. Suitable for hydrostatic level measurement on liquids. Zero and span can be adjusted internally.

 

Features

  • All stainless steel housing
  • Active temperature compensation
  • Strong flush diaphragm
  • Zero and span adjustable
  • All current process connections
  • ATEX and IECEx: Ex ia IIC T4 Ga

 

Technical details

 Measuring rang min. max.  0,1…100 bar
 Process temperature  -20 °C…+80 °C
 Accuracy  0,2 % of adjusted span
 Process connections 1” BSP and pulp- and paper connections with flush diaphragm, all current threaded connections
 Turn down  4:1
 Output  4 - 20 mA, 2-wire
 Adjustment  Zero and span internally adjustable
 Power supply  12 - 36 Vdc (Ex: 13 - 26,5 Vdc)
 Protection  IP66 (option IP68)
 Ambient temperature  -30 °C...+70 °C
 Diaphragm material  AISI 316L, option Hastelloy C or Gold plated
 Wetted parts  AISI 316L
 Electronics housing  AISI 304, option AISI 316
 Certificates/approvals

 Explosion safety: ATEX Ex-ia, IECEx Ex-ia and EAC Ex-ia
 Marine approvals: Lloyd's, DNV, BV, CCS, ABS, KR
 Functional safety: SIL2

 

Applications

Non hygienic level measurement of liquids where a flush diaphragm is needed. Examples are water, wastewater and oil. Because of the flush diaphragm very suitable for liquids which can cause clogging like pulp, paper and starch. For the pulp and paper industry specific process connections are available.

 

Accessories

  • Welding nipples for several connections

 

  Send your question

 

Downloads 

download documentatie
download handleidingen
download certificaten
Brochures
Manuals
Certificates
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Previous Next

Level Transmitter 8000-SAN with metallic diaphragm

The all stainless series 8000-SAN level transmitter has a flush diaphragm. Various hygienic connections, flanges or threaded connections. Application in the food industry, pharmaceutical industry and chemical industry. Zero and span can be adjusted internally.

 

Features

  • All stainless steel housing
  • Active temperature compensation
  • Strong flush diaphragm
  • Zero and span adjustable
  • Many hygienic process connections, also EHEDG and 3-A certified

 

Technical details

 Measuring range min. max.  0,04…100 bar
 Process temperature  -20 °C…+100 °C (145 °C /45 min), option HT max. 280 °C
 Accuracy  0,2 % of adjusted span
 Process connections  Hygienic connections, flanges and threaded connections, all with flush diaphragm
 Turn down  4:1
 Output  4-20 mA, 2-wire
 Adjustment  Zero and span internally adjustable
 Power supply  12 - 36 Vdc (Ex: 13 - 26,5 Vdc)
 Protection  IP66 (option IP68)
 Ambient temperature  -30 °C...+70 °C
 Diaphragm material  AISI 316L, option Hastelloy C, Tantalum or Gold plated
 Wetted parts  AISI 316L
 Electronics housing  AISI 304, option AISI 316
 Certificates/approvals

 Explosion safety : ATEX Ex-ia, IECEx Ex-ia and EAC Ex-ia
 Sanitary standard : EHEDG, 3-A
 Marine approvals : Lloyd's, DNV, BV, CCS, ABS, KR
 Functional safety : SIL2

 

Applications

Hydrostatic level measurement of liquids where a flush diaphragm is needed. Application mainly in the food industry, pharmaceutical industry and chemical industry. The transmitter is suitable for cleaning in place, both CIP and SIP.

 

Accessories

  • Welding nipples for several connections

 

Send your question

 

Downloads 

download documentatie
download handleidingen
download certificaten
Brochures
Manuals
Certificates
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Previous Next

Level Transmitter 8000-VALVE

The series 8000-valve is an all stainless level transmitter fitted in a valve. The transmitter with flush diaphragm can be removed from the process during operation. Zero and span can be adjusted internally.

 

Features

  • Removable during operation
  • All stainless steel construction
  • Strong flush diaphragm
  • Zero and span adjustable
  • Valves 1” en 1,5”

 

Technical details

 Measuring range min. max.  0,1…10 bar
 Process temperature  -20 °C…+85 °C
 Accuracy  0,2 % of adjusted span
 Process connections  Threaded connections, flanges and welding flange
 Turn down  4:1
 Output  4-20 mA 2-wire
 Adjustment  Zero and span adjustable
 Power supply  12 - 36 Vdc
 Protection  IP66 (option IP68)
 Ambient temperature  -30 °C...+70 °C
 Diaphragm material  AISI 316L, option Hastelloy C, Tantalum or Gold plated
 Wetted parts  AISI 316L
 Electronics housing  AISI 304, optie AISI 316

 

Applications

Level measurement mainly for clogging media where a flush diaphragm is needed. For example in the pulp and paper industry. The Transmitter can easily be removed from the process for cleaning and calibration.

 

Send your question

 

Downloads 

download documentatie
download handleidingen
Brochures
Manuals
 
 
 
 
Previous Next

Intelligent Level Transmitter 2000 with metallic diaphragm

The all stainless series 2000 pressure transmitter has a flush diaphragm. Suitable for hydrostatic level measurement on liquids. This microprocessor based transmitter can easily be programmed using the three push buttons and display.

 

Features

  • All stainless steel housing
  • Easy adjustable using 3 push buttons, without test pressure
  • Strong flush diaphragm
  • Active temperature compensation
  • Tank linearisation

 

Technical details

 Measuring range min. max.  0,1…100 bar
 Process temperature  -20 °C…+80 °C
 Accuracy  0,1 % of adjusted span
 Procesaansluitingen  1” BSP and pulp- and paper connections with flush diaphragm, all current threaded connections
 Turn down  10:1
 Output  4-20 mA 2-wire, option HART protocol
 Adjustment  With 3 push buttons and display, without test pressure or with HART
 Power supply  12 - 36 Vdc (Ex: 12 - 26,5 Vdc)
 Protection  IP66 (option IP68)
 Ambient temperature  -20 °C...+70 °C
 Diaphragm material  AISI 316L, option Hastelloy C or Gold plated
 Wetted parts  AISI 316L
 Electronics housing  AISI 304, option AISI 316
 Certificates/approvals

 Explosion safety: ATEX and IECEx Ex-nA, Ex-ia, Ex-ib and Ex-ec, EAC Ex-ia
 Marine approvals: Lloyd's, DNV, CCS, BV, ABS,
 Functional safety: SIL2

 

Applications

Non hygienic level measurement of liquids where a flush diaphragm is needed. Examples are water, wastewater and oil. Because of the flush diaphragm very suitable for liquids which can cause clogging like pulp, paper and starch. For the pulp and paper industry specific process connections are available.

 

Accessories

  • Welding nipples for several connections

 

  Send your question

 

Downloads 

download documentatie
download handleidingen
download certificaten
download software
Brochures
Manuals
Certificates
Software
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Previous Next

Intelligent Level Transmitter 2000-SAN with metallic diaphragm

The all stainless series 2000-SAN level transmitter has a flush diaphragm. Various hygienic connections, flanges or threaded connections. Application in the food industry, pharmaceutical industry and chemical industry. This microprocessor based transmitter can easily be programmed using the three push buttons and display.

 

Features

  • All stainless steel housing
  • Easy adjustable using 3 push buttons, without test pressure
  • Strong flush diaphragm
  • Active temperature compensation
  • Tank Linearisation

 

Technical details

 Measuring range min. max.   0,04…100 bar
 Process temperature  -20 °C…+100 °C (145 °C /45 min), option HT max. 280 °C
 Accuracy  0,1 % of adjusted span
 Process connections  Hygienic connections, flanges and threaded connections, all with flush diaphragm  
 Turn down  10:1
 Output  4-20 mA 2-wire, option HART protocol
 Adjustment  Hygienic connections, flanges and threaded connections, all with flush diaphragm
 Power supply  12 - 36 Vdc (Ex: 12 - 26,5 Vdc)
 Protection  IP66 (option: IP68)
 Ambient temperature  -20 °C...+70 °C
 Diaphragm material  AISI 316L, option Hastelloy C, Tantalum or Gold plated
 Wetted parts  AISI 316L
 Electronics housing  AISI 304, option AISI 316
 Certificates/approvals

 Explosion safety: ATEX and IECEx Ex-nA, Ex-ia, Ex-ib and Ex-ec, EAC Ex-ia
 Marine approvals: Lloyd's, DNV, BV, CCS, ABS,
 Functional safety: SIL2

 Sanitary standard: EHEDG, 3-A

 

Applications

Hydrostatic level measurement of liquids where a flush diaphragm is needed. Application mainly in the food industry, pharmaceutical industry and chemical industry. The transmitter is suitable for cleaning in place, both CIP and SIP.

 

Accessories

  • Welding nipples for several connections

 

Send your question

 

Downloads 

download documentatie
download handleidingen
download certificaten
download software
Brochures
Manuals
Certificates
Software
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

About Klay

Dutch manufacturer of process instrumentation. A flexible organisation and wide diversity in design of products. Our instruments are being used for industrial automation.

Contact

Klay Instruments B.V.
Nijverheidsweg 5
7991 CZ Dwingeloo
Tel +31 521 591 550
E-mail info@klay.nl